Model HFC-204
For Gas Flow Measuring And Controlling Requirements:
HVOF Flame Spray Applications
R&D and Process Flows
Pollution Monitoring
Fuel/Air Ratio Gas Furnaces
Production Baking Ovens
Glass Manufacturing
Features
Inherently Linear Response
Excellent Rangeability
Modular Construction
± 1% Full-Scale Accuracy
15-Pin D Connector
Range
HFM: 500 to 15,000 SLPM
HFC: 500 to 1,500 SLPM
(Air Equivalent)
Design Features
The HFM/HFC Series of flow instruments is based on a modular design. At the heart
of each instrument is an insulated thermo electric sensor which provides enhanced
zero stability and allows installation in any orientation plane. This sensor
is designed to be removable/replaceable in the field to virtually eliminate
long down time due to clogging, the most common cause of failure in the industry.
Additionally, the HFM/HFC design features an integral filter and an easily
replaceable closed loop electronics card.* The HFC also features an externally
adjustable valve with easily replaceable flow orifices.
All of these standard features, when coupled with the instruments inherent linear
response to flow changes and Hastings Instruments long-proven reputation
for quality, result in the finest flowmeters and flow controllers available today.
HFM200 Mass Flow Meter with LFE
Hastings Model HFM-200 Flowmeters with an LFE offer the user fast, accurate measurement
of high-capacity gas flows, in ranges from 0450 SLPM up to 0-15,000 SLPM.
The instrument is available with a 15-pin D connector.
The laminar flow elements (smoothed, flanged, or threaded) are available in various
sizes from 3/8" up to 8". Used in conjunction with the standard HFM
Flowmeter, these units can be combined to measure full-scale flows up to 15,000
SLPM and feature a typical pressure drop of 4.5" water scale at full-scale
flow.
*Note: After changing components, instruments require recalibration to meet accuracy
specifications.
Model HFC-204
The Hastings Model HFC-204 Flow Controller offers the user fast, accurate measurement
and control of high-capacity gas flows in ranges of 0-1500 SLPM. The instrument
is available with a 15-pin D connector. Built into each instrument
is a standard Hastings Model HFM mass flowmeter that features fine precision
and a long-recognized reputation for quality.
The High-Capacity Flow Controller is primarily stainless steel with easily replace-able
Viton®* O rings. The control valve is two-stage with a proportional
electromagnetic pilot, having control from 2% to 100% of full-scale capability.
Specifications
SPECIFICATIONS
HFM-200 with LFE Mass Flow Meter
Accuracy and Linearity
± 1% F.S.
Repeatability
± 0.05% F.S.
typical
Leak Integrity
< 1x10-7
sccs
Temperature Coefficient
±0.027%/°C
typical
Power
±15
VDC at ± 25 mA
Flow
Signal
(inherently
linear) 0-5 VDC
Wetted Material
316 SS, Viton®
, Au/Ni Braze
Connector
15-pin subminiature
D
Fittings
See LFE listing,
Selection Chart in Ordering Guide
Working Pressure
500 psig std.
SPECIFICATIONS
HFC-203 Mass Flow Controller
Accuracy and Linearity
±1% F.S.
Repeatability
±0.05% F.S.
typical
Std. Pressure Rating
500 psig
Control Valve DP
10 to 50 psid range
dependent
Power
±15 VDC at
+50 mA/-200 mA
In valve over-ride ±15 VDC at +65 mA/-220 mA